GM Service Manual Online
For 1990-2009 cars only

Starter PG-260

Application

Specification

No Load Test at 11.5 Volts

Current

60-120 Amps

Pinion Speed

2900-3400 RPM

Solenoid Windings Test at 11.5 Volts

Both Windings

30-50 Amps

Hold-in Windings

5-15 Amps