The CVRSS control module provides power (a regulated 8 volts) to each of the CVRSS position sensors. The control module also monitors this voltage supply for a fault condition which prevents proper regulation.
The position sensor supply voltage is outside the valid range of 6 to 9 volts.
• | The DTC is set when the CVRSS enters the Speed Dependent damping mode. |
• | The DTC is set when both of the ICCS2 Datalink Outputs are set to the default output states. |
• | The DTC is set when the SERVICE RIDE CONTROL message is displayed. |
The DTC turns HISTORY when the position sensor supply voltage returns to the valid range of 6 to 9 volts.
• | Use the scan tool. |
• | Use the On-Board diagnostic CLEAR RSS CODES feature. |
Important:
• | Do not backprobe the sensors, actuators, or any sealed connectors. |
• | When all the diagnostics and repairs are complete, clear the DTCs and verify the operation. |
The number(s) below refer to the step number(s) on the diagnostic table.
Determines if the fault is due to a short circuit to ground condition.
Determines if the fault is due to a short to voltage condition.
Checks for a short circuit to ground condition in the LR position supply.
Checks for a short circuit to ground condition in the RR position supply.
Checks for a short circuit to ground condition in the LF position supply.
Checks for a short circuit to ground condition in the RF position supply.
Checks for a short circuit condition between the LR position supply and ground.
Checks for a short circuit condition between the RR position supply and ground.
Checks for a short circuit condition between the LF position supply and ground.
Checks for a short circuit condition between the RF position supply and ground.
Checks for a short circuit to voltage condition in the LR position supply.
Checks for a short circuit to voltage condition in the RR position supply.
Checks for a short circuit to voltage condition in the LF position supply.
Checks for a short circuit to voltage condition in the RF position supply.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the CVRSS System Check performed? | -- | Go to Step 2 | |
Is the measurement less than the specified value? | 6 V | Go to Step 4 | Go to Step 3 | |
Is the measurement greater than the specified value? | 9 V | Go to Step 20 | Go to Step 28 | |
Is a short circuit to ground condition present? | -- | Go to Step 5 | Go to Step 6 | |
5 | Repair the short circuit to ground condition. Is the repair complete? | -- | -- | |
Check for continuity to ground on pin A5 of CVRSS connector C2 (harness side). Is a short circuit to ground condition present? | -- | Go to Step 7 | Go to Step 8 | |
7 | Repair the short circuit to ground condition. Is the repair complete? | -- | -- | |
Check for continuity to ground on pin A8 of CVRSS connector C2 (harness side). Is a short circuit to ground condition present? | -- | Go to Step 9 | Go to Step 10 | |
9 | Repair the short circuit to ground condition. Is the repair complete? | -- | -- | |
Check for a continuity to ground condition on pin A10 of CVRSS connector C2 (harness side). Is a short circuit to ground present? | -- | Go to Step 11 | Go to Step 12 | |
11 | Repair the short circuit to ground condition. Is the repair complete? | -- | -- | |
Check for continuity between pin A3 and pin B3 of CVRSS connector C2 (harness side). Is a short circuit to sensor ground condition present? | -- | Go to Step 13 | Go to Step 14 | |
13 | Repair the short circuit to sensor ground condition. Is the repair complete? | -- | -- | |
Check for continuity between pin A5 and pin B5 of the CVRSS connector C2 (harness side). Is a short circuit to sensor ground condition present? | -- | Go to Step 15 | Go to Step 16 | |
15 | Repair the short circuit to sensor ground condition. Is the repair complete? | -- | -- | |
Check for continuity between pin A8 and pin B8 of CVRSS connector C2 (harness side). Is a short circuit to sensor ground condition present? | -- | Go to Step 17 | Go to Step 18 | |
17 | Repair the short circuit to sensor ground condition. Is the repair complete? | -- | -- | |
Check for continuity between pin A10 and pin B10 of CVRSS connector C2 (harness side). Is a short circuit to sensor ground condition present? | -- | Go to Step 19 | Go to Step 28 | |
19 | Repair the short circuit to sensor ground condition. Is the repair complete? | -- | -- | |
Is the measurement greater than the specified value? | 10 V | Go to Step 21 | Go to Step 22 | |
21 | Repair the short circuit to voltage condition in CKT 431. Is the repair complete? | -- | -- | |
Measure the voltage between pin A5 of CVRSS connector C2 (harness side) and ground. Is the voltage greater than 10 volts? | -- | Go to Step 23 | Go to Step 24 | |
23 | Repair the short circuit to voltage condition in CKT 431. Is the repair complete? | -- | -- | |
Measure the voltage between pin A8 of CVRSS connector C2 (harness side) and ground. Is the measurement greater than the specified value? | 10 V | Go to Step 25 | Go to Step 26 | |
25 | Repair the short circuit to voltage condition in CKT 431. Is the repair complete? | -- | -- | |
Measure the voltage between pin A10 of CVRSS connector C2 (harness side) and ground. Is the measurement greater than the specified value? | 10 V | Go to Step 27 | Go to Step 28 | |
27 | Repair the short circuit to voltage condition in CKT 431. Is the repair complete? | -- | -- | |
28 |
Important: The controller must be calibrated. Is the CVRSS control module calibrated? | -- | -- |