Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Door Lock System Check? | -- | Go to Step 2 | |
2 |
Does the commanded state match the output? | -- | Go to Step 4 | Go to Step 3 |
3 | Replace the body control module (PZM). Refer to Body Control Module Replacement in Body Control System. Did you complete the repair? | -- | -- | |
4 |
Is the voltage within the specified range? | 10-15 V | Go to Step 6 | Go to Step 5 |
5 | Repair the open or the short to ground in CKT 2040 (ORN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
6 | Connect a J 39200 digital multimeter (DMM) between the power door lock relay terminals D and C. Is the voltage within the specified range? | 10-15 V | Go to Step 8 | Go to Step 7 |
7 | Repair the open in CKT 1250 (BLK). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
8 |
Does the power door locks lock? | -- | Go to Step 12 | Go to Step 9 |
9 | Test for an open or a short to ground in CKT 294 (TAN) between the power door lock relay and S325. Is the circuit OK? | -- | Go to Step 11 | Go to Step 10 |
10 | Repair the open or the short to ground in CKT 294. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
11 | Repair the open or the short to ground in CKT 295 (GRY). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
12 |
Is the repair complete? | -- | -- |