Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Interior Lights System Check performed? | -- | Go to Step 2 | |
2 | Measure the voltage to ground from the IP compartment lamp connector terminal A (ORN). Is battery voltage measured? | -- | Go to Step 3 | Go to Step 5 |
3 | Measure the voltage from the IP compartment lamp connector terminal A (ORN) to terminal B (BLK). Is battery voltage measured? | -- | Go to Step 4 | Go to Step 6 |
4 | Replace the IP compartment lamp. Is the repair complete? | -- | -- | |
5 | Repair the open in CKT 640 (ORN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
6 | Repair the open in CKT 150 (BLK). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- |