Tools Required
J 8001
Dial Indicator
Set
- Attach
J 8001
rod to the extension housing using
one of the bolt holes.
- Mount Dial Indicator
J 8001
on the rod and index it to the output shaft. Set the dial indicator
to 0.
Important: If the end play is not correct, repeat the main case selective washer
procedure.
- Lift the output shaft upwards. The end play should measure 0.36 to 0.8 mm
(0.014 to 0.03 in).
- Remove the tools.