Removal Procedure
- Remove the transmission. Refer to
Transmission Replacement .
- Remove the torque converter (1) from the transmission.
- Remove the torque converter seal bolts.
- Remove the torque converter seal.
- Remove the input shaft seal from the input shaft.
Installation Procedure
- Install the input shaft seal to the input shaft.
- Install the torque converter seal.
Notice: Refer to Fastener Notice in the Preface section.
- Install the converter seal bolts.
Tighten
Tighten the torque converter seal bolts to 3 N·m (26 lb in).
- Install the torque converter (1). Push the torque converter into position while rotating. The torque converter must be fully seated.
• | The torque converter must be fully seated on the turbine shaft |
• | The torque converter must be fully seated in the pump drive gear |
- Install the transmission. Refer to
Transmission Replacement .
Important: It is recommended that transmission adaptive pressure (TAP) information be reset.
Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, The ECM, PCM or TCM will
need to relearn TAP values. Transmission performance may be affected as new TAP values are learned.
- Reset the TAP values. Refer to
Adapt Function.