Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Power Window Schematics | |||
1 | Did you review the Power Windows Description and Operation? | Go to Step 2 | Go to Symptoms - Doors |
2 | Verify that the all power windows inoperative fault is present. Do the power windows operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 9 |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 6 |
5 |
Does the test lamp illuminate? | Go to Step 8 | Go to Step 7 |
6 | Test the power window switch express signal circuit of the LF door switch for a short to voltage, a short to ground or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 11 | Go to Step 8 |
7 | Test the ground circuit of the LF door switch for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 11 | Go to Step 8 |
8 | Inspect for poor connections at the LH door switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 11 | Go to Step 10 |
9 | Repair the open in the battery positive voltage circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 11 | -- |
10 | Replace the LH door switch. Refer to Power Accessory Switch Panel Replacement . Did you complete the repair? | Go to Step 11 | -- |
11 | Operate the system in order to verify the repair. Did you find and correct the condition? | System OK | Go to Step 2 |