Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Interior Lights Schematics | |||
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | |
2 |
Are both the LH and RH sunshade illuminated mirror lamps inoperative? | Go to Step 3 | Go to Step 4 |
3 |
Does the test lamp illuminate? | Go to Step 9 | Go to Step 10 |
4 |
Does the test lamp illuminate? | Go to Step 12 | Go to Step 5 |
5 |
Does the test lamp illuminate? | Go to Step 6 | Go to Step 7 |
6 | Probe the ground circuit of the inoperative sunshade illuminated mirror lamp with a test lamp that is connected to B+. Does the test lamp illuminate? | Go to Step 11 | Go to Step 8 |
7 | Repair the open or high resistance in the supply voltage circuit of the inoperative sunshade illuminated mirror lamp. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 13 | -- |
8 | Repair the open or high resistance in the ground circuit of the inoperative sunshade illuminated mirror lamp. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 13 | -- |
9 | Repair the open or high resistance in the ground circuit that feeds both the RH and LH sunshade illuminated mirror lamps. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 13 | -- |
10 | Repair the open or high resistance in the supply voltage circuit that feeds both the RH and LH sunshade illuminated mirror lamps. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 13 | -- |
11 | Replace the inoperative sunshade illuminated mirror. Refer to Vanity Mirror Lamp Replacement . Did you complete the repair? | Go to Step 13 | -- |
12 | Replace the inoperative sunshade illuminated mirror bulb. Did you complete the repair? | Go to Step 13 | -- |
13 |
Do the LH and RH sunshade illuminated mirror lamps operate properly? | System OK | Go to Step 2 |