Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Interior Lights Schematics | |||
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | |
2 |
Does the test lamp illuminate? | Go to Step 3 | Go to Step 6 |
3 | Probe the ground circuit of the I/P compartment lamp connector with a test lamp that is connected to B+. Does the test lamp illuminate? | Go to Step 10 | Go to Step 4 |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 7 |
5 |
Does the IP compartment lamp turn ON? | Go to Step 9 | Go to Step 8 |
6 | Repair an open or high resistance in the I/P compartment lamp supply voltage circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 11 | -- |
7 | Repair an open or high resistance in the I/P compartment lamp switch ground circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 11 | -- |
8 | Repair an open or high resistance in the I/P compartment switch signal circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 11 | -- |
9 | Replace the IP compartment lamp switch. Refer to Instrument Panel Compartment Lamp Switch Replacement in Instrument Panel, Gauges and Console. Did you complete the repair? | Go to Step 11 | -- |
10 | Replace the IP compartment lamp. Refer to Instrument Panel Compartment Lamp Replacement . Did you complete the repair? | Go to Step 11 | -- |
11 |
Does the IP compartment lamp operate properly? | System OK | Go to Step 2 |