Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Exterior Lights Schematics | |||
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | |
2 | Verify that hazard lamps are inoperative. Are the hazard lamps operating properly? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Do the turn signals operate properly? | Go to Step 4 | |
4 | Determine if all the hazard lamps are inoperative, the LH hazard lamps are inoperative, or the RH hazard lamps are inoperative. Are all the hazard lamps inoperative? | Go to Step 5 | Go to Step 7 |
5 |
Does the test lamp illuminate? | Go to Step 6 | Go to Step 11 |
6 |
Did you find and correct the condition? | Go to Step 13 | Go to Step 12 |
7 | Are the LH hazards lamps inoperative? | Go to Step 8 | Go to Step 9 |
8 | Test the hazard switch LH signal circuit (FM3) for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 12 |
9 | Test the hazard switch RH signal circuit (FU3) for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 12 |
11 | Repair an open or high resistance in the battery supply voltage circuit (A9) of the hazard warning switch. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 13 | -- |
12 | Replace the hazard warning switch. Refer to Hazard and Turn Signal Flasher Replacement in Instrument Panel, Gauges and Console. | Go to Step 13 | -- |
13 |
Do the hazard lamps operate properly? | System OK | Go to Step 2 |