Removal Procedure
- Remove the R/H sound insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel,
Gages and Console.
- Remove the front floor air outlet from the HVAC module.
The RH duct temperature sensors are located in the HVAC module just
above where the floor air outlets connect to the module.
- Using a flat bladed tool,
disconnect the electrical connector from the air temperature sensor.
- Turn the temperature sensor 180 degrees.
Carefully remove the air temperature sensor from the HVAC module.
Installation Procedure
- Carefully insert the air
temperature sensor into the HVAC module.
Turn the air temperature sensor 180 degrees.
- Connect the electrical connector to the air temperature sensor.
- Install the front floor air outlet.
- Install the R/H sound insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel,
Gauges and Console.