Removal Procedure
- Remove the I/P compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel,
Gages and Console.
- Disconnect the blower control module electrical connector.
- Disconnect the blower motor electrical connector.
- Release the blower control module retainer tabs.
- Remove the blower control module from the blower motor housing.
Installation Procedure
- Position the blower control
module to the blower motor housing.
- Connect the blower control module retainer tabs.
Ensure the retainer tabs are fully seated.
- Connect the blower motor electrical connector.
- Connect the blower control module electrical connector.
- Install the I/P compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages and Console.