J 35910 Seal Clamp Pliers
Do not damage the inner race.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the clamp to 136 N·m (100 lb ft).
Specification
Continue to tighten the small seal retaining clamp until the base of
the omega (ohms) shape has a gap width of 2.15 mm (0.085 in).
Important: The seal must not be dimpled, stretched or out of shape in any way. If the seal is not shaped correctly, equalize pressure on the seal and shape the seal properly by hand.
Tighten
Tighten the clamp to 176 N·m (130 lb ft).
Specification
Continue to tighten the large seal retaining clamp until the base of
the omega (ohms) shape has a gap width of 2.60 mm (0.102 in).