Step | Action | Yes | No |
---|---|---|---|
1 | Were you sent here from Symptoms? | Go to Step 2 | Go to Symptoms |
2 |
Does the air flow from the selected HVAC ducts? | Go to Step 3 | |
3 | Did the customer concern that the air temperature is normal at first, then changes during higher engine RPM? | Go to Step 7 | Go to Step 4 |
4 | With the engine running, take a vacuum reading at the manifold vacuum port. Does engine vacuum exist? | Go to Step 6 | Go to Step 5 |
5 | Repair the no-vacuum condition. Is the repair complete? | Go to Step 27 | -- |
6 | Take a vacuum reading of the supply line at the vacuum control solenoids. Is the vacuum reading the same as the engine vacuum? | Go to Step 11 | Go to Step 8 |
7 |
Does the system lose vacuum after turning OFF the engine? | Go to Step 8 | Go to Step 4 |
8 |
Do the vacuum lines leak? | Go to Step 9 | Go to Step 10 |
9 | Repair or replace the collapsed or the leaking vacuum line. Is the repair complete? | Go to Step 27 | -- |
10 | Inspect the vacuum reservoir tank for leaks. Does the vacuum reservoir leak? | Go to Step 23 | Go to Step 11 |
11 |
Does the system hold a vacuum? | Go to Step 18 | Go to Step 16 |
12 |
Does the system hold a vacuum? | Go to Step 18 | Go to Step 17 |
13 | Inspect for leaking or collapsed vacuum lines between the recirculation actuator and the recirculation actuator control solenoid. Do the vacuum lines leak? | Go to Step 15 | Go to Step 18 |
14 | Inspect for leaking or collapsed vacuum lines between the heater water valve and the vacuum control solenoid. Do the vacuum lines leak? | Go to Step 15 | Go to Step 12 |
15 | Repair or replace the collapsed or leaking vacuum line. Is the repair complete? | Go to Step 27 | -- |
16 |
Does the valve hold a vacuum? | Go to Step 14 | Go to Step 26 |
17 |
Does the actuator hold a vacuum? | Go to Step 13 | Go to Step 22 |
18 |
Does the recirculation door bind? | Go to Step 19 | Go to Step 20 |
19 | Repair the binding door. Is the repair complete? | Go to Step 27 | -- |
20 | Test the operation of the vacuum control solenoid to the recirculation actuator. Refer to DTC 28 Air Circ. Valve Voltage Low or Open CKT or DTC 29 Air Circulation Valve Voltage High . Is the vacuum control assembly operating properly? | Go to Step 21 | Go to Step 24 |
21 | Test the operation of the hot water bypass control solenoid. Is the control solenoid operating properly? | Go to Step 27 | Go to Step 25 |
22 | Replace the recirculation actuator. Refer to Air Inlet Actuator Replacement . Is the replacement complete? | Go to Step 27 | -- |
23 | Replace the vacuum reservoir tank. Refer to Vacuum Tank Replacement . Is the replacement complete? | Go to Step 27 | -- |
24 | Replace the recirculation vacuum control solenoid. Is the replacement complete? | Go to Step 27 | -- |
25 | Replace the hot water bypass control solenoid. Is the replacement complete? | Go to Step 27 | -- |
26 | Replace the hot water valve. Refer to Heater Water Valve Replacement . Is the replacement complete? | Go to Step 27 | -- |
27 | Cycle the HVAC controls in order to verify proper operation. Did you correct the condition? | System OK | Go to Step 2 |