Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the BCM Diagnostic System Check? | -- | Go to Step 2 | |||||||
2 |
Did the SECURITY indicator lamp light? | -- | Go to Step 3 | Go to Step 4 | ||||||
3 | The condition is not present at this time. Refer to Inducing Intermittent Fault Conditions in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 8 | -- | ||||||
4 |
Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 5 | ||||||
5 | Inspect for poor connections at the following:
Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 6 | ||||||
6 |
Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 7 | ||||||
7 | Inspect the power and ground circuits for poor connections at BCM connectors C1 and C2. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 9 | ||||||
8 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | -- | ||||||
9 | Replace the BCM. Did you complete the replacement? | -- | Go to Step 8 | -- |