Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Backup Lamp Schematics | |||
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | |
2 |
Do the backup lamps operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Determine if one backup lamp is inoperative or both backup lamps are inoperative. Is one backup lamp inoperative? | Go to Step 10 | Go to Step 4 |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 8 |
5 | Connect a fused jumper between the battery positive voltage circuit and the backup lamp supply voltage circuit of the automatic transmission range switch connector. Do the backup lamps illuminate? | Go to Step 11 | Go to Step 6 |
6 |
Does the test lamp illuminate? | Go to Step 7 | Go to Step 9 |
7 | Repair an open or high resistance in the ground circuit of the backup lamps. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 12 | -- |
8 | Repair an open or high resistance in the battery supply voltage circuit of the automatic transmission range switch. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 12 | -- |
9 | Repair an open or high resistance in the backup lamps supply voltage circuit of the backup lamps. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 12 | -- |
10 |
Has the repair been made? | Go to Step 12 | -- |
11 | Replace or adjust the automatic transmission range switch. Refer to Manual Shift Shaft Position Switch Replacement in Automatic Transmission. Did you complete the repair? | Go to Step 12 | -- |
12 |
Do the backup lamps operate properly? | System OK | Go to Step 3 |