Modules connected to the Class 2 serial data circuit monitor for serial data communications during normal vehicle operation. Operating information and commands are exchanged among the modules. Connecting a scan tool to the DLC allows communication with the modules for diagnostic purposes.
The diagnostic procedure assumes that all modules are powered. When you are uncertain whether this condition is met, perform the Diagnostic System Check for the module in question. Diagnostic trouble codes (DTCs) may be set due to this symptom and during this diagnostic procedure. Complete the diagnostic procedure in order to ensure all the DTCs are diagnosed and cleared from memory.
• | Use a J 35616-A when probing or checking electrical connector terminals. The J 35616-A prevents terminal damage, plus checks for proper terminal contact tension. |
• | If a short to B+ is present a history U1301 will set in the modules. Refer to DTC U1301 Class 2 Short to Battery . |
• | If a short to ground is present a history U1300 will set in the modules. Refer to DTC U1300 Class 2 Short to Ground . |
• | If the malfunction is intermittent refer to Intermittents and Poor Connections Diagnosis in Wiring Systems. |
• | Disconnecting modules and turning the ignition switch to ON may cause DTCs in these modules. Check for DTCs in each module upon completion of the required repair. |
A partial malfunction in the Class 2 serial data circuit uses a different procedure from a total malfunction of the Class 2 serial data circuit.
DTCs U1300 and/or U1301 may be retrieved with a history status. These DTCs are not the cause of the present condition.
A state of health DTC with a history status indicates the malfunction occurred when the ignition was on.
Data link connector terminals 2 and 5 provide the connection to the Class 2 serial data circuit and the signal ground circuit respectively.
The Class 2 serial data circuit is shorted to voltage or ground. The condition may be due to the wiring or due to a malfunction in one of the modules. When testing the wiring for a short, make sure there is not a module connected to the wire being tested.
Since the short is not in the wiring harness the malfunction is due to one of the modules.
If there are no current DTCs that begin with a U, the communication malfunction has been repaired.
The communication malfunction may have prevented diagnosis of the customer complaint.
Step | Action | Yes | No | ||||
---|---|---|---|---|---|---|---|
1 | Does the scan tool power up? | Go to Step 2 | |||||
Does the scan tool communicate with any module on the Class 2 serial data circuit? | Go to Step 3 | Go to Step 5 | |||||
Did you record any DTCs in the range of U1000 to U1255? | Go to Step 4 | Go to Diagnostic Aids | |||||
Is U1255 the only DTC displayed in the previously specified range? | Go to DTC U1000 and DTC U1255 Class 2 Communication Malfunction | ||||||
Did you find and correct the condition? | Go to the Applicable Diagnostic System Check | Go to Step 6 | |||||
6 | Test the DLC ground circuit terminal 5 for an open. Refer to Testing for Continuity in Wiring Systems. Did you find and correct the condition? | Go to the Applicable Diagnostic System Check | Go to Step 7 | ||||
Did you find and correct the condition? | Go to Step 13 | Go to Step 8 | |||||
Does the scan tool communicate with the BCM? | Go to Step 9 | Go to Step 10 | |||||
9 | Continue connecting the disconnected modules and attempting to communicate after each connection until communication cannot be established or all the modules are reconnected. Did you find the condition? | Go to Step 11 | Go to Diagnostic Aids | ||||
10 | Inspect for poor connections/terminal tension at the Class 2 serial data circuit of the BCM. Did you find and correct the condition? | Go to Go to Step 13 | Go to Step 12 | ||||
11 | Replace the most recently reconnected module. Refer to the appropriate repair instructions for module replacement. Did you complete the replacement? | Go to Step 13 | -- | ||||
12 | Replace the BCM. Did you complete the replacement? | Go to Step 13 | -- | ||||
Did you record any DTCs which begin with a U and with a current status? | Go to Step 15 | Go to Step 14 | |||||
Did you record any DTCs which do not begin with a U? | Go to Step 15 | Go to Step 17 | |||||
15 | Diagnose the DTCs as directed by the diagnostic procedures for the particular module or malfunction. Did you complete the action? | Go to Step 16 | -- | ||||
16 | Did you diagnose all of the DTCs? | Go to Step 17 | Go to Step 15 | ||||
17 | Clear the DTCs using the scan tool. Did you complete the action? | System OK | -- |