This test requires both a fully charged battery and a generator
test stand to operate the generator.
- Make connections as shown,
except leave the carbon pile turned off. The ground polarity of the generator
and battery must be the same. The battery must be fully charged. Use a 30-500 ohm
resistor between the battery and the L terminal.
- Slowly increase the generator speed and observe the voltage.
- If the voltage is uncontrolled and increases above 16 volts,
the rotor field is shorted, the regulator is not working properly, or both.
A shorted rotor field coil can cause repeat regulator failure.
- If the voltage is below 16 volts, increase speed and turn
on and adjust the carbon pile to obtain maximum amperage output. Maintain
the voltage above 13 volts.
- If the output is with 15 amperes of the generators rated
output, the generator is good.
- If the output is not within 15 amperes of the generators
rated output, replace the generator.