Step
| Action
| Value(s)
| Yes
| No
|
1
| Did you perform the Fog Lamps System Check?
| --
| Go to
Step 2
| Go to
Fog Lights System Check
|
2
|
- Disconnect the instrument cluster connector.
- Turn the fog lamps ON.
- Use the DMM to measure the voltage between terminal 5 of the instrument
cluster connector and a known good ground.
Is the measured voltage within the specified value?
| B+
| Go to
Step 4
| Go to
Step 3
|
3
|
- Locate an open or a high resistance in circuit FP40.
- Repair the open or the high resistance in circuit FP40.
Is the repair complete?
| --
| Go to
Step
5
| --
|
4
|
- Inspect the fog lamp indicator bulb.
- If the fog lamp indicator bulb is OK, replace the instrument cluster.
Refer to
Instrument Cluster Indicator Lamp Replacement
in Instrument Panel, Gauges and Console.
Is the replacement complete?
| --
| Go to
Step
5
| --
|
5
|
- Connect all connectors and components that were disconnected.
- Verify that the fog lamp indicator operates properly.
Does the fog lamp indicator operate properly?
| --
| Go to
Fog Lights System Check
| Go to
Step
1
|