Removal Procedure
- Remove the instrument
panel (IP) compartment. Refer to
Instrument Panel Compartment Replacement
.
- Remove the cover from the IP compartment door.
- Remove the door handle from the IP compartment.
- Insert the key into the lock cylinder.
Important: The cylinder tumblers are spring-loaded and if not retained with the
key, the tumblers will spring out of the cylinder upon removal. If you are
not replacing the cylinder, tape the tumblers into place before removing the
key. For more information on lock cylinder coding procedures refer to
Key and Lock Cylinder Coding
.
- Unseat the retaining tangs from the lock cylinder with a small screwdriver.
- Gently press the cylinder from the back side of the handle out
through the front.
Installation Procedure
- With the key still in
place within the lock cylinder, gently insert the cylinder into the front
of the handle until the retainer tangs are seated.
Important: Verify correct cylinder installation by applying moderate pressure to
the back side of the cylinder. The cylinder should not move from the mounted
position.
- Remove the key.
- Install the handle to the IP compartment door.
- Install the cover to the IP compartment door.
- Install the IP compartment. Refer to
Instrument Panel Compartment Replacement
.