Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Blower Controls System Check performed? | -- | Go to Blower Controls System Check | |
2 | Inspect HEATER BLOWER fuse 33. Is the fuse open? | -- | ||
3 | Test CKT A465 or the circuit to the A/C compressor relay for a short to ground. Is there a short to ground in one of the circuits? | -- | ||
4 | Test for voltage at the HEATER BLOWER fuse block terminal (one terminal is hot at all times). Is the voltage within the specified value? | B+ | ||
5 | Repair the short to ground. Refer to Wiring Repairs. Is the repair complete? | -- | -- | |
6 | Replace the HEATER BLOWER fuse. Is the replacement complete? | -- | Go to Blower Controls System Check | -- |
7 |
Is the voltage within the specified value? | B+ | ||
8 | Locate and repair the open voltage feed circuit. Refer to the Power Distribution schematics. Is the repair complete? | -- | Go to Blower Controls System Check | -- |
9 |
Is the voltage within the specified value? | B+ | ||
10 |
Is the voltage within the specified value? | B+ | ||
11 |
Does the blower motor operate? | -- | ||
12 | Replace the blower controller. Is the replacement complete? | -- | Go to Blower Controls System Check | -- |
13 | Locate and repair the open in CKT F812 (BLK). Is the repair complete? | -- | Go to Blower Controls System Check | -- |
14 | Locate and repair the open in CKT A465 (RED). Is the repair complete? | -- | Go to Blower Controls System Check | -- |
15 | Replace the blower motor. Is the replacement complete? | -- | Go to Blower Controls System Check | -- |