Improper Air Delivery
Step
| Action
| Value(s)
| Yes
| No
|
1
| Was the Air Delivery System
Check performed?
| --
|
Go
to Step 2
| Go to Air Delivery System Check
|
2
|
• | Select the actuator tests from the Air Conditioning SPECIAL FUNCTIONS
menu. |
• | Select one actuator test at a time and command the actuator from
0% to 100%. |
• | Monitor the air flow when commanding the selected actuator (e.g.,
good air flow should be felt when the floor actuator is commanded to 100%
and none when commanded to 0%.) |
Does the scan tool display the status ACTIVE when the actuator is commanded?
| --
|
Go to Step 3
|
Go to Step 4
|
3
| Is good air flow felt when the actuator selected is
commanded from 100% to 0%?
| --
| System OK
|
Go to Step 4
|
4
|
• | Check the actuator that failed for mechanical binding. Repair
as needed. |
• | Check the circuit wiring between the heater and A/C control and
the actuator. Repair as needed. Refer to the applicable DTC table related
to the actuator for assistance. |
Is the repair complete?
| --
| System OK
| --
|