Step
| Action
| Value(s)
| Yes
| No
|
DEFINITION:
Power door lock inoperative from the LH front side door lock switch.
|
1
| Was the Power Door Locks System Check performed?
| --
|
Go to Step 2
| Go to
Power Door Locks System Check
.
|
2
|
- Disconnect the LH front side door lock switch connector.
- Use the DMM to measure the resistance between terminal 4 of the
LH front side door lock switch connector and a known good ground.
Is the measured resistance within the specified value?
| Less than 5 ohms
|
Go to Step 4
|
Go to Step 3
|
3
|
- Locate an open or a high resistance in circuit F12.
- Repair the open or the high resistance in circuit F12.
Is the repair complete?
| --
|
Go to Step
9
| --
|
4
|
- Disconnect the BCM connector C1.
- Use the DMM to measure the resistance between terminal 1 of the
LH front side door lock switch connector and terminal A08 of the BCM connector
C1.
Is the measured resistance within the specified value?
| Less than 5 ohms
|
Go to Step 6
|
Go to Step 5
|
5
|
- Locate an open or a high resistance in circuit FX805.
- Repair the open or the high resistance in circuit FX805.
Is the repair complete?
| --
|
Go to Step
9
| --
|
6
| Use a DMM to measure the resistance between terminal 2 of the LH front
side door lock switch connector and terminal A06 of the BCM connector C1.
Is the measured resistance within the specified value?
| Less than 5 ohms
|
Go to Step 8
|
Go to Step 7
|
7
|
- Locate an open or a high resistance in circuit FY805.
- Repair the open or the high resistance in circuit FY805.
Is the repair complete?
| --
|
Go to Step
9
| --
|
8
| Replace the LH front side door lock switch. Refer to
Door Lock Switch Replacement
in Doors.
Is the replacement complete?
| --
|
Go to Step
9
| --
|
9
|
- Connect all connectors and components that were disconnected.
- Verify that the power door locks operate properly from the LH
front side door lock switch.
Do the power door locks operate properly from LH front side door lock
switch?
| --
| System OK
|
Go to Step 1
|
Step
| Action
| Value(s)
| Yes
| No
|
DEFINITION:
Power door lock inoperative from the RH front side door lock switch.
|
1
| Was the Power Door Locks System Check performed?
| --
|
Go to Step 2
| Go to
Power Door Locks System Check
.
|
2
|
- Disconnect the RH front side door lock switch connector.
- Use the DMM to measure the resistance between terminal 4 of the
RH front side door lock switch connector and a known good ground.
Is the measured resistance within the specified value?
| Less than 5 ohms
|
Go to Step 4
|
Go to Step 3
|
3
|
- Locate an open or a high resistance in circuit F12.
- Repair the open or the high resistance in circuit F12.
Is the repair complete?
| --
|
Go to Step
9
| --
|
4
|
- Disconnect the BCM connector C1.
- Use the DMM to measure the resistance between terminal 1 of the
RH front side door lock switch connector and terminal A08 of the BCM connector
C1.
Is the measured resistance within the specified value?
| Less than 5 ohms
|
Go to Step 6
|
Go to Step 5
|
5
|
- Locate an open or a high resistance in circuits FX805 and/or FX804.
- Repair the open or the high resistance in circuits FX805 and/or
FX804.
Is the repair complete?
| --
|
Go to Step
9
| --
|
6
| Use a DMM to measure the resistance between terminal 2 of the RH front
side door lock switch connector and terminal A06 of the BCM connector C1.
Is the measured resistance within the specified value?
| Less than 5 ohms
|
Go to Step 8
|
Go to Step 7
|
7
|
- Locate an open or a high resistance in circuits FY805 and/or FY804.
- Repair the open or the high resistance in circuits FY805 and/or
FY804.
Is the repair complete?
| --
|
Go to Step
9
| --
|
8
| Replace the RH front side door lock switch. Refer to
Door Lock Switch Replacement
in Doors.
Is the replacement complete?
| --
|
Go to Step
9
| --
|
9
|
- Connect all connectors and components that were disconnected.
- Verify that the power door locks operate properly from the RH
front side door lock switch.
Do the power door locks operate properly from RH front side door lock
switch?
| --
| System OK
|
Go to Step 1
|