Step | Action | Values | Yes | No |
---|---|---|---|---|
1 | Was the Instrument Cluster System Check performed? | -- | Go to Step 2 | Go to Instrument Cluster System Check |
2 |
Is the voltage reading within the specified range? | B+ | Go to Step 4 | Go to Step 3 |
3 | Test for an open or a poor connection in CKT XU600. If OK, replace the gauge cluster. Is the repair or replacement complete? | -- | Go to Step 5 | -- |
4 | Test for an open ground circuit or a poor connection at connector C102 terminal 6. If OK, replace the engine oil level sensor. Is the repair or replacement complete? | -- | Go to Step 5 | -- |
5 |
Does the low engine oil level indicator operate properly? | -- | System OK | Go to Step 2 |