Step
| Action
| Value(s)
| Yes
| No
|
1
| Was the Headlight System Check performed?
| --
|
Go to Step 2
| Go to
Headlight System Check
.
|
2
|
- Disconnect the instrument cluster connector.
- Disconnect the BCM connector C1.
- Use the DMM to measure the resistance between terminal 9 of the
instrument cluster connector and terminal C08 of the BCM connector C2.
Is the measured resistance within the specified value?
| Less than 5 ohms
|
Go to Step 4
|
Go to Step 3
|
3
|
- Locate an open or a high resistance in circuit M75.
- Repair the open or the high resistance in circuit M75.
Is the repair complete?
| --
|
Go to Step
5
| --
|
4
|
- Check the high beam indicator bulb.
- If the high beam indicator bulb is OK, replace the instrument
cluster. Refer to
Instrument Cluster Gage Replacement
in Instrument Panel, Gauges and Console.
Is the replacement complete?
| --
|
Go to Step
5
| --
|
5
|
- Connect all connectors and components that were disconnected.
- Verify that the high beam indicator operates properly.
Does the high beam indicator operate properly?
| --
| System OK
|
Go to Step 1
|