Removal Procedure
Caution: Gasoline or gasoline vapors are highly flammable. A fire could occur
if an ignition source is present. Never drain or store gasoline or diesel
fuel in an open container, due to the possibility of fire or explosion. Have
a dry chemical (Class B) fire extinguisher nearby.
- Remove the oil filler cap.
- Disconnect the IAC valve electrical connector.
- Remove the 2 retaining screws.
- Remove the IAC valve.
Installation Procedure
Important: You can re-use the original gasket if the gasket is still in good condition.
- Thoroughly clean any gasket material from both of the sealing surfaces.
- Install the gasket.
- Install the IAC valve and tighten screws to 3 N·m
(27 lb in).
- Connect the IAC valve electrical connector.
- Install the oil filler cap.