Important: Use a catch basin to collect escaping coolant.
Do not reuse the seal.
Important: Ensure the O-ring seal is properly positioned to the water pump.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the water pump bolts to 25 N·m (18 lb ft).
EN 46104 Water Pump Pulley Holding Tool
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the water pump bolts to 10 N·m (89 lb in).
Tighten
Tighten the water pump pulley bolts to 12 N·m (106 lb in).
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten