Notice: Tighten the control valve assembly bolts in a spiral pattern starting from the center. If the bolts are tightened in a random pattern, the valve bores may become distorted, which can inhibit valve operation.
Important: Do not damage the solenoid filter screens when installing the control valve.
Tighten
Tighten the bolts to 11 N·m (97 lb in).
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
• | Tighten the control valve body bolts in a spiral pattern to 11 N·m (97 lb in). |
• | Tighten the pressure switch bolts to 11 N·m (97 lb in). |
• | Tighten the manual detent spring bolt to 24 N·m (18 lb ft). |