Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Did you perform the Power Mirrors System Check? | -- | Go to Step 2 | |||||
2 |
Is the voltage within the specified range? | 10-15 V | Go to Step 3 | Go to Step 7 | ||||
3 |
Is the voltage within the specified range? | 10-15 V | Go to Step 8 | Go to Step 4 | ||||
4 |
Is the voltage within the specified range? | 10-15 V | Go to Step 6 | Go to Step 5 | ||||
5 | Repair the open or the short to ground in the following circuits. Refer to Wiring Repairs in Wiring Systems:
Did you complete the repair? | -- | -- | |||||
6 | Repair the open or the short to ground in CKT 82 (LT BLU). Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |||||
7 | Replace the power mirror switch. Refer to Power Mirror Switch Replacement . Did you complete the repair? | -- | -- | |||||
8 | Replace the suspect outside power mirror. Refer to Power Mirror Replacement . Did you complete the repair? | -- | -- |