Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Windows System Check? | -- | Go to Step 2 | |
2 |
Is the voltage within the specified range? | 10-15 V | Go to Step 3 | Go to Step 4 |
3 |
Is the voltage within the specified range? | 10-15 V | Go to Step 5 | Go to Step 6 |
4 | Repair an open in CKT 141 (BRN). Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |
5 |
Is the voltage within the specified range? | 10-15 V | Go to Step 11 | Go to Step 7 |
6 | Test for an open or a short to ground in CKT 1136 (GRY). Is the circuit OK? | -- | Go to Step 10 | Go to Step 8 |
7 | Test for an open or a short to ground in CKT 164 (DK BLU). Is the circuit OK? | -- | Go to Step 10 | Go to Step 9 |
8 | Repair the open or the short to ground in CKT 1136 (GRY). Refer to Wiring Repairs Did you complete the repair? | -- | -- | |
9 | Repair the open or the short to ground in CKT 164 (DK BLU). Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |
10 | Replace the left front door lock/window switch. Refer to Door Lock and Side Window Switch Replacement . Did you complete the repair? | -- | -- | |
11 | Connect a fused jumper between the express down module terminal A (BRN) and terminal D (BRN). Does the left front power window motor operate? | -- | Go to Step 12 | Go to Step 13 |
12 |
Does the left front power window motor operate? | -- | Go to Step 16 | Go to Step 15 |
13 | Test for an open or a short to ground in CKT 165 (BRN). Is the circuit OK? | -- | Go to Step 15 | Go to Step 14 |
14 | Repair the open or the short to ground in CKT 165 (BRN). Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |
15 | Replace the left front power window motor. Refer to Power Window Motor Replacement . Did you complete the repair? | -- | -- | |
16 | Replace the express down module. Did you complete the repair? | -- | -- |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Windows System Check? | -- | Go to Step 2 | |
2 |
Is the voltage within the specified range? | 10-15 V | Go to Step 3 | Go to Step 4 |
3 |
Is the voltage within the specified range? | 10-15 V | Go to Step 5 | Go to Step 6 |
4 | Repair an open in CKT 141. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |
5 |
Is the voltage within the specified range? | 10-15 V | Go to Step 11 | Go to Step 7 |
6 | Test for an open or a short to ground in CKT 1136 (GRY). Is there an open or a short to ground in CKT 1136? | -- | Go to Step 8 | Go to Step 10 |
7 | Test for an open or a short to ground in CKT 164 (DK BLU). Is there an open or a short to ground in CKT 164? | -- | Go to Step 9 | Go to Step 10 |
8 | Repair the open or the short to ground in CKT 1136 (GRY). Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |
9 | Repair the open or the short to ground in CKT 164 (DK BLU). Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |
10 | Replace the left front power window switch. Refer to Front Side Door Window Switch Replacement . Did you complete the repair? | -- | -- | |
11 | Connect a fused jumper between the express down module terminal A and terminal D. Does the left front power window motor operate? | -- | Go to Step 12 | Go to Step 13 |
12 |
Does the left front power window motor operate? | -- | Go to Step 16 | Go to Step 15 |
13 | Test for an open or a short to ground in CKT 165 (BRN). Is there an open or a short to ground in CKT 165? | -- | Go to Step 14 | Go to Step 15 |
14 | Repair the open or the short to ground in CKT 165. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |
15 | Replace the left front power window motor. Refer to Power Window Motor Replacement . Did you complete the repair? | -- | -- | |
16 | Replace the express down module. Did you complete the repair? | -- | -- |