Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Remote Keyless Entry System Check? | -- | Go to Step 2 | |
2 | Is the remote keyless entry system inoperative from both transmitters? | -- | Go to Step 3 | Go to Step 4 |
3 | Reprogram the transmitters. Refer to Transmitter Programming . Do the transmitters operate? | -- | Go to Step 5 | |
4 |
Does the transmitter operate? | Go to Step 10 | ||
5 |
Is the voltage within the specified range? | 10-15 V | Go to Step 7 | Go to Step 6 |
6 | Repair the open or the short to ground in CKT 40 (ORN). Is the repair complete? | -- | -- | |
7 | Measure the voltage between the RFA module connector terminals E16 and F16. Is the voltage within the specified range? | 10-15 V | Go to Step 9 | Go to Step 8 |
8 | Repair the open in CKT 1050 (BLK). Is the repair complete? | -- | -- | |
9 | Replace the RFA module. Refer to Remote Control Door Lock Receiver Replacement . Is the repair complete? | -- | -- | |
10 |
Is the repair complete? | -- | -- |