Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Instrument Cluster System Check? | -- | Go to Step 2 | |
2 |
Does the LOW WASHER FLUID warning go out? | -- | Go to Step 3 | Go to Step 4 |
3 | Replace the washer fluid level switch. Is the repair complete? | -- | -- | |
4 | Inspect CKT 99 (BLK/WHT) for a short to ground between washer fluid level switch connector terminal B and instrument cluster connector C2 terminal B3. Is the wiring OK? | -- | Go to Step 5 | Go to Step 6 |
5 | Replace the instrument cluster. Is the repair complete? | -- | -- | |
6 | Repair the short to ground in CKT 99 (BLK/WHT). Is the repair complete? | -- | -- |