Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Audible Warnings System Check before processing? | -- | Go to Step 2 | |
2 |
Is the measured resistance less than the specified value? | 5 ohms | Go to Step 4 | Go to Step 3 |
3 | Does the keyless entry work? | -- | Go to Step 6 | |
4 | Inspect the MALL module connector C2 for proper terminal contact. Is the contact OK? | -- | Go to Step 5 | -- |
5 | Replace the MALL module. Is the repair complete? | -- | -- | |
6 | Inspect CKT 653 (DK BLU/WHT) for an open. Is the circuit OK? | -- | Go to Step 7 | Go to Step 10 |
7 |
Is the measured resistance less than the specified value? | 5 ohms | Go to Step 11 | Go to Step 8 |
8 |
Are the circuits OK? | -- | Go to Step 9 | Go to Step 10 |
9 |
Are the components OK? | -- | -- | |
10 | Repair the open in CKT 80 (LT GRN) or in CKT 150 (BLK). Is the repair complete? | -- | -- | |
11 | Inspect the RFA module connector for proper terminal contact. Is the contact OK? | -- | Go to Step 12 | -- |
12 | Replace the RFA module. Is the repair complete? | -- | -- |