Step

Action

Value(s)

Yes

No

1

Did you perform the Audible Warnings System Check before processing?

--

Go to Step 2

Go to Audible Warnings System Check

2

  1. Turn the ignition switch to OFF.
  2. Disconnect the body control module (MALL) connector C1.
  3. Measure the voltage from connector C1 terminal H (harness side) to ground.

Does the measured voltage match the specified value?

12 V

Go to Step 4

Go to Step 3

3

  1. Inspect CKT 1540 (ORN) for an open.
  2. Inspect CKT 1540 (ORN) for a short to ground.
  3. Inspect the power door lock fuse for an open.

Are the circuits OK?

--

Go to Intermittents and Poor Connections Diagnosis

Go to Step 10

4

  1. Turn the ignition switch to OFF.
  2. Measure the voltage from connector C1 terminal H (harness side) to ground.

Does the measured voltage match the specified value?

12 V

Go to Step 6

Go to Step 5

5

  1. Inspect CKT 640 (ORN/BLK) for an open.
  2. Inspect CKT 640 (ORN/BLK) for a short to ground.
  3. Inspect the interior lamp fuse for an open.

Are the circuits OK?

--

Go to Intermittents and Poor Connections Diagnosis

Go to Step 10

6

  1. Turn the ignition switch to OFF.
  2. Measure the voltage from connector C1 terminal H (harness side) to terminal D (harness side) .

Does the measured voltage match the specified value?

12 V

Go to Step 8

Go to Step 7

7

Inspect CKT 150 (BLK) for an open.

Is the circuit OK?

--

Go to Audible Warnings System Check

Go to Step 10

8

  1. Disconnect the MALL module connector C2.
  2. Turn the ignition switch to ON.
  3. Measure the voltage from connector C2 terminal C13 (harness side) to ground.

Does the measured voltage match the specified value?

12 V

Go to Step 11

Go to Step 9

9

  1. Inspect CKT 39 (PNK) for an open.
  2. Inspect CKT 39 (PNK) for a short to ground.
  3. Inspect the IGN 1 fuse for an open.

Are the circuits OK?

--

Go to Intermittents and Poor Connections Diagnosis

Go to Step 10

10

Repair the open or short to ground.

Is the repair complete?

--

Go to Audible Warnings System Check

--

11

Inspect the MALL module connectors for proper terminal contact.

Is the contact OK?

--

Go to Step 12

--

12

Replace the MALL module.

Is the repair complete?

--

Go to Audible Warnings System Check

--