Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Instrument Cluster System Check? | -- | Go to Step 2 | |
2 |
Does the lamp light momentarily? | -- | Go to Step 3 | |
3 |
Are any DTCs present? | -- | Go to the applicable DTC diagnostic chart in Engine Controls | Go to Step 4 |
4 | Using the Scan Tool , turn on the CHECK OIL LEVEL light. Does the lamp light? | -- | Go to Step 5 | |
5 |
Is the CHECK OIL LEVEL lamp lit? | -- | Go to Step 6 | Go to Step 7 |
6 |
Does the amperage measure greater than the specified value? | 500 mA | Go to Step 8 | Go to Step 9 |
7 | Inspect CKT 1173 for an open. Is the circuit OK? | -- | Go to Step 10 | Go to Step 11 |
8 | Inspect CKT 1173 (BRN/WHT) for a short to voltage. Is the circuit OK? | -- | Go to Step 12 | Go to Step 11 |
9 | Replace the PCM. Is the repair complete? | -- | -- | |
10 | Inspect connector C2 cavity A8 for proper terminal contact. Is the connection OK? | -- | Go to Step 12 | Go to Step 12 |
11 | Repair CKT 1173. Is the repair complete? | -- | -- | |
12 | Replace the instrument cluster. Is the repair complete? | -- | -- |