Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Content Theft Deterrent (CTD) System Check? | -- | Go to Step 2 | |
2 | Does the horn operate properly? | -- | Go to Step 3 | Go to Horns System Check in Horns |
3 | Connect a 3-amp fused jumper between CKT 28 (BLK/WHT) terminal E2 at the remote function actuator (RFA) module and ground. Does the horn operate? | -- | Go to Step 4 | Go to Step 5 |
4 | Replace the RFA module. Refer to Remote Control Door Lock Receiver Replacement in Keyless Entry. Did you complete the repair? | -- | -- | |
5 | Repair the open in CKT 28 (BLK/WHT). Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- |