UART-based communication systems have a master of the serial data line and remote transceivers. The master controls the message traffic on the serial data line by polling the HVAC programmer. The master then waits for the proper response.
• | The ignition is on. |
• | The circuit is open or shorted. |
Code B1036 is set.
Using a Scan Tool .
Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 |
Did the Scan Tool establish communications on CKT 800? | -- | Go to Step 2 | Go to Scan Tool Does Not Communicate with UART Data Line in Wiring Systems | ||||
2 | Attempt to establish communications between the Scan Tool and the HVAC system (Non-E and C). Did the Scan Tool establish communications with the HVAC system (Non-E and C)? | -- | Go to Step 4 | Go to Step 3 | ||||
3 |
Is the voltage within the specified range at each cavity? | 3-5 V | Go to Step 5 | Go to Step 6 | ||||
4 | Code B1038 can only be viewed as a history code when a serial data line condition is not current. A current serial data line condition cannot be accessed through the Scan Tool unless the condition occurs in the climate control system. Is the condition occurring in the climate control system? | -- | Go to Step 5 | Go to Scan Tool Does Not Communicate with UART Data Line in Wiring Systems | ||||
5 | Replace the HVAC programmer. Refer to Programmer Replacement . Is the repair complete? | -- | System OK | -- | ||||
6 |
Is the repair complete? | -- | System OK | -- | ||||
7 | Inspect for an open or poor connection in CKT 800 (TAN/BLK) to HVAC programmer terminal C2 terminal C7 and terminal C8. Refer to Intermittents and Poor Connections Diagnosis in Wiring Systems. Was an open or poor connection found and the repair complete? | -- | System OK | Go to Step 5 |