GM Service Manual Online
For 1990-2009 cars only

Inspection and Testing

Inspect the following starter motor components:

  1. The drive pinion.
  2. • The pinion should turn freely in the overrunning direction and turn with some degree of resistance in the drive direction.
    • Check the pinion teeth to see that they have not been chipped, cracked, or excessively worn. Badly chipped pinion teeth can indicate chipped ring gear teeth. Replace the flywheel if necessary.

       Notice: Do not clean or immerse the starter motor parts in grease dissolving solvents. The solvents will dissolve the grease packed in the drive or the bearings, and may damage the armature or the field coil insulation.

    • The starter drive requires no lubrication, but it should be wiped clean.

    Object Number: 300542  Size: SH
  3. The solenoid hold-in windings by connecting an ammeter (1) and switch in series with a 12 volt battery and the solenoid terminal on the solenoid switch.
  4. 2.1. Connect a voltmeter (2) to the solenoid terminal and the ground.
    2.2. Disconnect the motor lead from the solenoid and tape the lead to prevent contact.
    2.3. Connect the carbon pile across the battery.
    2.4.  Adjust the voltage to 10 volts and note the ammeter reading. The starter motor reading should be 6-12 A.

    Notice: Do not allow the solenoid pull-in current to flow for more than 15 seconds at a time. The windings can be damaged by overheating. Also, the current draw readings will decrease as the windings heat up.

  5. The solenoid hold-in windings and the pull-in windings by making connections as for the previous test.
  6. 3.1. Ground the solenoid motor terminal.
    3.2.  Adjust the voltage to 10 volts and note the ammeter reading. The starter motor reading must be 30-45 A.
       • The current reading will change as the windings heat up.
       • The current draw readings that are over the specifications indicate shorted turns or a ground in the solenoid windings.
       • The current draw readings that are under the specifications indicate excessive resistance.
       • No reading indicates an open.