The porous plastic expansion
(orifice) tube, with its porous plastic inlet and outlet filters and brass
orifice tube, is located between the condenser outlet and evaporator inlet.
It provides a restriction to the high-pressure liquid refrigerant in the
liquid line, metering the flow of refrigerant to the evaporator as a low-pressure
liquid. The expansion (orifice) tube is protected from contamination by
filters on both the inlet and outlet sides. When system diagnostics indicate
a restricted expansion (orifice) tube, it may not be necessary to replace
the expansion (orifice) tube. Metal chips, flakes, or slivers found on the
inlet filter may be removed with compressed air ONLY and the expansion (orifice)
tube may be reused if:
• | The plastic frame is not broken (1). |
• | The inlet filter is not plugged with fine gritty material (3). |