Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Inspect the STRG WHL CONT fuse for an open. Is STRG WHL CONT fuse open? | -- | Go to Step 5 | Go to Step 2 |
2 | Using a test light, connect between connector C205 terminal B and ground. Does the test light illuminate? | -- | Go to Step 3 | Go to Step 6 |
3 | Using a test light, connect between connector C205 terminal C and B+. Does the test light illuminate? | -- | Go to Step 4 | Go to Step 7 |
4 | Repair a poor connection or open in circuit 1450. Is the repair complete? | -- | -- | |
5 | Repair a short to B+ in circuit 1458. Is the repair complete? | -- | -- | |
6 | Repair a poor connection or open in circuit 1458. Is the repair complete? | -- | -- | |
7 | Repair a poor connection or open in circuit 1796. Is the repair complete? | -- | -- |