Step
| Action
| Value(s)
| Yes
| No
|
1
|
- Disconnect the blower motor resistor.
- Turn the ignition switch to the RUN position.
- Place the heater-A/C control in the VENT position.
- Place the blower switch in the OFF position.
- Use a test light to backprobe between the following blower motor
resistor harness connector and ground:
Does the test light illuminate for any of the tests?
| --
|
Go to Step 2
|
Go to Step
5
|
2
|
- Leave the test light connected to the same terminal that illuminated
the test light.
- Disconnect the heater-A/C control connector C1.
Does the test light illuminate?
| --
|
Go to Step 3
|
Go to Step 4
|
3
| Repair the short to B+ in the following circuit:
- LO - Blower motor resistor harness connector terminal B
(circuit 60).
- M1 - Blower motor resistor harness connector terminal A
(circuit 63).
- M2 - Blower motor resistor harness connector terminal D
(circuit 72).
- M3 - Blower motor resistor harness connector terminal C
(circuit 73).
- HI - Blower motor resistor harness connector terminal F
(circuit 52).
Has the repair been made and the system rechecked?
| --
| System OK
| --
|
4
| Replace the heater-A/C control.
Refer to
Control Assembly Replacement
.
Is the repair complete?
| --
| System OK
| --
|
5
| Replace the blower motor resistor.Refer to
Blower Motor Resistor Replacement
.
Is the repair complete?
| --
| System OK
| --
|