Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 |
Is the measured voltage within the specified range? | 9-14 V | Go to Step 2 | Go to Step 6 | ||||||
2 | Measure the voltage from the generator BATTERY terminal to ground. Is the measured voltage within the specified range? | 9-14 V | Go to Step 3 | Go to Step 9 | ||||||
3 |
Is the measured voltage within the specified range? | 13-16 V | Go to Step 4 | Go to Step 10 | ||||||
4 | Load test the generator. Refer to Charging System Check . Does the generator operate properly? | -- | Go to Step 5 | Go to Step 10 | ||||||
5 | Replace the battery. Refer to Battery Replacement . Is the repair complete? | -- | System OK | -- | ||||||
6 | Check for a poor connection or open in circuit 225. Is there a poor connection or open in circuit 225? | -- | Go to Step 7 | |||||||
7 | Repair the poor connection or open in circuit 225. Is the repair complete? | -- | System OK | -- | ||||||
8 | Service the PCM. Refer to Powertrain Control Module Replacement/Programming in Engine Controls - 3.8L or Powertrain Control Module Replacement/Programming in Engine Controls - 3.1L. Is the repair complete? | -- | System OK | -- | ||||||
9 | Repair the open in circuit 2 or the fusible link to the generator BATTERY terminal. Is the repair complete? | -- | System OK | -- | ||||||