Removal Procedure
- Remove the right sound insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gages,
and Console.
- Remove the instrument panel (I/P)
compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages, and Console.
- Remove the body control module (BCM) and the HVAC programmer from
the brackets and lay aside.
- Disconnect the electrical connector from the right air temperature actuator.
- Remove the right air temperature actuator retaining screws (1).
- Remove the right air temperature actuator.
Installation Procedure
- Install the right air temperature actuator.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the right air temperature actuator retaining screws (1).
Tighten
Tighten the screws to 1.4 N·m (12 lb in).
- Connect the electrical connector to the right air temperature actuator.
- Install the BCM and the HVAC programmer into the appropriate brackets.
- Install the I/P compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages, and Console.
- Install the right sound insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gages,
and Console.
- Recalibrate the actuators. Refer to
Actuator Recalibration
.