Battery Voltage: The scan tool displays 0-20 volts.
The scan tool displays the voltage as received on the battery positive voltage circuit
to the module.
Generator Lamp Circuit Status: The scan tool displays Fault/OK/Invalid
State. The scan tool displays Fault until the engine is started then OK is displayed.
GEN F-Terminal Signal: The scan tool displays 0-100%.
The scan tool displays 0-5% until the engine is running, then the percentage
value varies depending on electrical loads.
Generator L-Terminal Signal Command: The scan tool displays
OK/No Output. The scan tool displays No Output until the engine is started and the
PCM receives a signal from the generator then OK is displayed.
Heated Seats Cycling Due to Load Mgt.: The scan tool displays
Yes/No. The Scan tool displays No unless the Load management system is active.
IMS: The scan tool displays Park, Park/Reverse, Reverse, Reverse/Neutral,
Neutral, Neutral/Drive 4, Drive 4, Drive 4/Drive 3, Drive 3, Drive 3/Drive 2, Drive
2, Drive 2/Drive 1, Drive 1, INVALID, and OPEN. The scan tool displays the physical
position of the Internal Mode Switch (IMS) of the transmission.
Ignition 1 Signal: The scan tool displays 0-20 volts.
The scan tool displays the voltage as received on the Ignition 1 circuit to the PCM.
Inadvert. Power Output: The scan tool displays On/Off. The scan
tool displays On unless the Load management system is active.
Starter Enable Relay Circuit Status: The scan tool displays
Fault/OK/Invalid State. The scan tool displays Fault until the ignition is placed
into the START position then OK is displayed.
Starter Relay Command: The scan tool displays ON/OFF. The scan
tool displays Off until the ignition is placed into the CRANK position, then it reads
On.
Volt Lamp: The scan tool displays On/Off. The scan tool displays
On when the PCM sends a class 2 message to the IPC to turn on the charge indicator
lamp then On is displayed.