Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition ON/Engine OFF | |||
Battery Voltage | Data | Volts | 12.6 Volts |
Heated Seats Cycling Due to Load Mgt. | Outputs | Yes/No | No |
Inadvert. Power | Outputs | On/Off | On |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition ON/Engine OFF | |||
Battery Voltage | Data | Volts | 12.6 Volts |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition ON/Engine OFF | |||
Volt Lamp | Inputs | On/Off | On |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition ON/Engine OFF | |||
Battery Voltage | Data | Volts | 12.6 Volts |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Engine Running | |||
GEN F-Terminal Signal | Engine Data 2 | % | 45% |
GEN L-Terminal Signal Command | Engine Data 2 | On/Off | On |
Ignition 1 Signal | Engine Data 1, Engine Data 2 | Volts | 12.6 Volts |
Starter Enable Relay Circuit Status | Output Driver Data | Fault/OK/Invalid State | OK |
Starter Relay Command | Engine Data 2 | On/Off | Off |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition ON / Transmission in Park | |||
IMS | Transmission Data | Park, Park/Reverse, Reverse, Reverse/Neutral, Neutral, Neutral/Drive 4, Drive 4, Drive 4/Drive 3, Drive 3, Drive 3/Drive 2, Drive 2, Drive 2/Drive 1, Drive 1, INVALID, OPEN | Park |