Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 4 | Go to Step 3 | |||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK | Go to Symptoms - HVAC Systems - Automatic in HVAC Systems - Automatic |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center Discharge Air Temperature | |
---|---|---|---|---|
Low Side | High Side | |||
13-18°C (55-65°F) | 0-100% | 175-261 kPa (26-33 psi) | 1120-1450 kPa (163-210 psi) | 8°C (46.4°F) |
19-24°C (66-75°F) | Below 40% | 175-261 kPa (25-38 psi) | 1151-1358 kPa (167-215 psi) | 9°C (48.2°F) |
Above 40% | 179-283 kPa (26-41 psi) | 1240-1560 kPa (180-226 psi) | 12°C (53°F) | |
25-29°C (76-85°F) | Below 35% | 208-293 kPa (30-43 psi) | 1350-1600 kPa (196-232 psi) | 11°C (52°F) |
35-49% | 219-303 kPa (32-44 psi) | 1390-1610 kPa (202-234 psi) | 12°C (54°F) | |
Above 50% | 227-322 kPa (33-47 psi) | 1420-1640 kPa (206-238 psi) | 14°C (57°F) | |
30-35°C (86-95°F) | Below 30% | 241-331 kPa (35-48 psi) | 1500-1760 kPa (218-255 psi) | 14°C (57°F) |
Above 30% | 250-346 kPa (36-50 psi) | 1510-1750 kPa (219-254 psi) | 16°C (61°F) | |
Above 50% | 263-368 kPa (38-53 psi) | 1530-1750 kPa (222-254 psi) | 18°C (64°F) | |
36-41°C (96-105°F) | Below 20% | 276-363 kPa (40-53 psi) | 1680-1930 kPa (244-280 psi) | 16°C (61°F) |
20-40% | 284-380 kPa (41-55 psi) | 1680-1910 kPa (244-277 psi) | 18°C (64°F) | |
Above 40% | 298-397 kPa (43-58 psi) | 1680-1880 kPa (244-273 psi) | 20°C (68°F) | |
42-46°C (106-115°F) | Below 20% | 315-397 kPa (46-58 psi) | 1870-2080 kPa (271-302 psi) | 18°C (64°F) |
Above 20% | 323-415 kPa (47-60 psi) | 1850-2030 kPa (269-295 psi) | 20°C (68°F) | |
47-49°C (116-120°F) | Below 30% | 357-427 kPa (52-62 psi) | 2000-2140 kPa (290-311 psi) | 21°C (70°F) |