GM Service Manual Online
For 1990-2009 cars only

The Keyless Entry Scan Tool Data List contains all of the keyless entry related parameters that are available on the scan tool. The parameters in the list are arranged in alphabetical order. The column, "Data List," indicates the location of the parameter within the scan tool menu selections. Use the Keyless Entry Scan Tool Data List as directed by a diagnostic table or in order to supplement the diagnostic procedures. Begin all of the diagnostic procedures with Diagnostic System Check - Remote Keyless Entry .

Use the Scan Tool Data List only after the following is determined:

    • There is no published DTC procedure nor published symptom procedure for the customer concern.
    • The DTC or symptom diagnostic procedure indicated by the diagnostic system check does not resolve the customer concern.

The Typical Data Values are obtained from a properly operating vehicle under the conditions specified in the first row of the Scan Tool Data List table. Comparison of the parameter values from the suspect vehicle with the Typical Data Values may reveal the source of the customer concern.

Scan Tool Parameter

Data List

Units Displayed

Typical Data Value

Ignition ON/Engine OFF/Headlamp Switch Off/Doors Closed

8-Digit GM Part Number

Module Information

8-Digit Number

25640963

# of Fob's Programmed

Key FOB Information

Fob 1-Fob 4

Fob 2

Accessory 1

Inputs

On/Off

On

Aware Output

Outputs

On/Off

On

Battery Voltage

Data

Volts

11.8 V

Calibration ID

Module Information

4-Digit Number

0963

Courtesy Lamp Output

Outputs

On/Off

Off

Exterior Lamp Output

Outputs

On/Off

Off

Horn Output

Outputs

On/Off

Off

Ignition 1

Inputs

On/Off

On

Key In Ignition

Inputs

On/Off

On

Key Pressed On Fob

Key FOB Information

Door Lock, Dr Door Unlock, All Door Unlock, Trunk, Fuel Door/Alarm

Dr Door Unlock

Last Fob Used

Key FOB Information

Fob #1 - Fob #4

Fob #1

Park Lamp Input

Inputs

On/Off

Off

Perimeter Lamp Output

Outputs

On/Off

Off

PROM ID

Module Information

4 Digit Number

7100

RAP Output

Outputs

On/Off

On

Security Lamp Output

Outputs

On/Off

Off

Theft Tamper Switch

Inputs

On/Off

Off

Trunk Release Output

Outputs

On/Off

Off