The retained accessory power (RAP) system allows the following
components to operate for approximately 10 minutes after the ignition
switch is turned off:
• | The sunroof (if equipped) |
• | The cellular telephone (if equipped) |
When the ignition switch is turned to the ACCY or the RUN position,
voltage is applied from the IP junction block WSW/RFA fuse to the remote function
actuator (RFA) module. When the RFA module grounds terminal 86
of the RAP relay, the RAP relay energizes and supplies power to the RDO/PH
fuse and the SUNRF fuse (if equipped).
When the ignition switch is turned to the OFF position, the voltage
from the IP junction block WSW/RFA fuse to the RFA module is removed. The
RFA module continues to ground terminal 86 of the RAP relay for
10 minutes or until any passenger compartment door is opened. The
RFA module receives the passenger compartment door status from the driver
door module (DDM) through the class 2 serial data line. When either
event occurs, power is removed from the rear junction block RDO/PH fuse
and the rear junction block SUNRF fuse (if equipped).