Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Remote Keyless Entry System Check performed? | -- | Go to Step 2 | |
2 |
Is the voltage within the specified range? | 10-15V | Go to Step 4 | Go to Step 3 |
3 | Repair the open or short to ground in CKT 2040 (ORN). Did you complete the repair? | -- | Go to Step 9 | -- |
4 | Measure the voltage between the RFA module connector terminal A15 and ground. Is the voltage within the specified range? | 10-15V | Go to Step 6 | Go to Step 5 |
5 | Repair the open or short to ground in CKT 39 (PNK). Did you complete the repair? | -- | Go to Step 9 | -- |
6 | Measure the voltage between the RFA module connector terminals A16 and B16. Is the voltage within the specified range? | 10-15V | Go to Step 8 | Go to Step 7 |
7 | Repair the open in CKT 650 (BLK). Did you complete the repair? | -- | Go to Step 9 | -- |
8 | Replace the RFA module. Refer to Remote Control Door Lock Receiver Replacement . Did you complete the repair? | -- | Go to Step 9 | -- |
9 |
Did you complete the repair? | -- | -- |