Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Instrument Cluster Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Is the measured voltage within the specified range? | 10-15 V | Go to Step 8 | Go to Step 3 |
3 | Inspect for an open or short in CKT 99 (BLK). Is the wiring OK? | -- | Go to Step 5 | Go to Step 4 |
4 | Repair the open or short to ground in CKT 99 (BLK). Did you complete the repair? | -- | -- | |
5 | Inspect instrument cluster connector C1 for proper terminal contact. Is the terminal contact OK? | -- | Go to Step 7 | Go to Step 6 |
6 | Repair the poor terminal contact. Did you complete the repair? | -- | -- | |
7 | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Did you complete the repair? | -- | -- | |
8 | Connect a DMM between connector terminal B (BLK) and terminal A (BLK). Is the measured voltage within the specified range? | 10-15 V | Go to Step 12 | Go to Step 9 |
9 | Inspect CKT 1350 (BLK) for an open. Is the wiring OK? | -- | Go to Step 11 | Go to Step 10 |
10 | Repair the open in CKT 1350 (BLK). Did you complete the repair? | -- | -- | |
11 | Inspect in-line connector C105 for proper terminal contact. Is the terminal contact OK? | -- | Go to Step 6 | |
12 | Inspect the washer fluid level switch connector for proper terminal contact. Is the terminal contact OK? | -- | Go to Step 13 | Go to Step 6 |
13 | Replace the washer fluid level switch. Did you complete the repair? | -- | -- |